CASE·FAULT-TOLERANT SOLUTION FOR AN OIL COMPANY
Fault-tolerant solution for an oil company
Together with cloud servers, the oil company uses its own equipment, which allows the creation of a geographically distributed and more reliable IT system.
Client profile
RNG is one of the leading oil and gas companies in the Far Eastern Federal District. It was founded in 2003 and is part of the Eastsib Holding Co. Since 2010, RNG has been holding a license for exploration and production of raw hydrocarbons within the territory of the Eastern Blocks of Srednebotuobinskoe oil-gas condensate field (EB SB OGCF), located in the south-western part of the Sakha (Yakutia) Republic. Since the process of exploration, production, and delivery of hydrocarbons requires the use of modern technologies and uninterrupted operation of the entire infrastructure, the oil company employs cloud solutions. This allows providing the required level of fault tolerance and scalability.
Challenges
Creation of a fault-tolerant system that meets the company's needs and protects the operability of its services even in case of serious failures at infrastructure facilities.
Solutions
We ensured channel fault tolerance and implemented Disaster Recovery so that if any of our data centers fail, the customer can restore its infrastructure in another data center. Below is the solution architecture.
- Cloud DC1 and Cloud DC2 are Cloud4U data centers, and On-prem DC1 and On-prem DC2 are client data centers.
- Datacenter Interconnect is the L2 link between our datacenters. The local network that hosts the client's virtual machines.
- Routers in On-Prem DC - any routers that support dynamic routing (preferably OSPF).
- Routers in Cloud DC - one router, to which the routers on the On-Prem sites are connected via the L2 channel. In the diagram, it is a Mikrotik Cloud Hosted Router.
To improve the resiliency of the channel, the technical experts of the client brought one channel to each data center. Thus were created L2 channels between Cloud DC1 - On-Prem DC1 and Cloud DC2 - On-Prem DC2.
The provider's engineers stretched client channels to the opposite data centers via an optical ring. Here is an interconnected structure:
Channel 1: On-Prem DC1 -> Cloud DC1 -> Cloud DC2
Channel 2: On-Prem DC2 -> Cloud DC2 -> Cloud DC1
There is also an L2 channel configured between On-Prem DC1 and On-Prem DC2. Therefore, the unavailability of any data center does not break network connectivity to other data centers, routes to other data centers are rebuilt by the dynamic routing protocol.
Virtual machines in Cloud4U cloud can be either hosted in any of the data centers, simultaneously in both, or migrate from one data center to another while working (cold migration through vCAV or Cloud Director with virtual machines turned off). The network connectivity is not compromised because the network in the cloud data center is a single L2 segment (broadcast domain).
To implement a disaster recovery solution for all virtual machines in the DC cloud data center, VMware Cloud Director Availability runs VM replication to the opposite cloud data centers. In case of a disaster in any of the data centers, virtual machines can be started in the other data center. It takes about 4 minutes to manually restart a virtual router in a data center.
This Disaster Recovery solution is not automatic, but it is reliable and functional. In the event of failure of any of Cloud4U data centers, the client can quickly restore their infrastructure in another data center.
Project Results
The company received a robust IT system, protected from external threats and capable of maintaining high loads. In case of failure of the company's servers, data will not be lost because it is stored in the Cloud4U cloud.
Benefits for the Client
- Increased reliability and reliability of the infrastructure.
- Fast recovery of the workflow and functioning of the services in the case of an accident or force majeure in the main data center.
- Guaranteed return to normal operation within the timeframe specified by the selected solution.
- Maintaining network connectivity in the event of a data center outage.
- Increased resiliency of the channel.